Page 12 - Bock Semi Hermetic Condensing Units
P. 12
Bock Semi-Hermetic Condensing Units
Factory Fitted Options - Available to special order
Condenser Fan Control Housing Oil Separator Options Crankcase
Condensing Auto HP switch Electronic Metal unit Standard System Solenoid Valve Oil Separator Heater
Unit Model (on/off) control speed controller housing c/w hand SOV & Sight Glass Heater
RCS HGX 4/465-4S PS1-A5A RGE-Z1Q4 AC19H W55889 1/4" 4" Band Inc. standard
RCS HGX 4/465-4SH PS1-A5A - AC20HE W55889 1/4" 4" Band Inc. standard
RCS HAX 4/465-4 PS1-A5A RGE-Z1Q4 AC17H W55889 1/4" 4" Band Inc. standard
RCS HGX 4/555-4S PS1-A5A RGE-Z1Q4 AC19H W55889 1/4" 4" Band Inc. standard
RCS HGX 4/555-4SH PS1-A5A - AC20HE W55889 1/4" 4" Band Inc. standard
RCS HAX 4/555-4L PS1-A5A RGE-Z1Q4 AC17H W55889 1/4" 4" Band Inc. standard
RCS HAX 4/555-4 PS1-A5A RGE-Z1Q4 AC19H W55889 1/4" 4" Band Inc. standard
RCS HGX 4/650-4S PS1-A5A - AC20HE W55889 1/4" 4" Band Inc. standard
RCS HAX 4/650-4 PS1-A5A RGE-Z1Q4 AC19H W55889 1/4" 4" Band Inc. standard
RCS HGX 5/725-4S PS1-A5A - AC20HE W55889 1/4" 4" Band Inc. standard
RCS HGX 5/725-4SH PS1-A5A - AC21S W55889 1/4" 4" Band Inc. standard
RCS HAX 5/725-4 PS1-A5A - AC20HE W55889 1/4" 4" Band Inc. standard
RCS HGX 5/830-4S PS1-A5A - AC21S W55889 1/4" 4" Band Inc. standard
RCS HAX 5/830-4 PS1-A5A - AC20HE W55889 1/4" 4" Band Inc. standard
RCS HGX 5/945-4S PS1-A5A - AC21S W559011 1/4" 4" Band Inc. standard
RCS HAX 5/945-4 PS1-A5A - AC20HE W55889 1/4" 4" Band Inc. standard
RCS HGX 6/1080-4S PS1-A5A - AC22S W559011 1/4" 4" Band Inc. standard
RCS HAX 6/1080-4 PS1-A5A - AC20HE W55889 1/4" 4" Band Inc. standard
RCS HGX 6/1240-4S PS1-A5A - AC22S W559011 1/4" 4" Band Inc. standard
RCS HGX 6/1240-4SH PS1-A5A - AC21D W559011 1/4" 4" Band Inc. standard
RCS HGX 6/1410-4S PS1-A5A - AC22S W559011 1/4" 4" Band Inc. standard
RCS HGX 6/1410-4SH PS1-A5A - AC21D W559011 1/4" 4" Band Inc. standard
RCS HGX 7/1620-4S PS1-A5A - AC21D W569213 3/8" 6" Band Inc. standard
RCS HGX 7/1620-4SH PS1-A5A - AC22D W569213 3/8" 6" Band Inc. standard
RCS HGX 7/1860-4S PS1-A5A - AC21D W569213 3/8" 6" Band Inc. standard
RCS HGX 7/1860-4SH PS1-A5A - AC22D W569213 3/8" 6" Band Inc. standard
RCS HGX 7/2110-4S PS1-A5A - AC22D W569213 3/8" 6" Band Inc. standard
RCS HGX 8/2470-4S PS1-A5A - AC22D W569417 3/8" 6" Band Inc. standard
RCS HGX 8/2830-4S PS1-A5A - AC22D W569417 3/8" 6" Band Inc. standard
RCS HGX 8/3220-4S PS1-A5A - AC22D W569417 3/8" 6" Band Inc. standard
Factory Fitted Options - Specification :
Condenser Fan Control Oil Separator Options
HP On/Off control:- Only applicable to twin fan units and only one fan is Standard System:- comprises an impingement type oil separator including
controlled. a vibration eliminator in the discharge line and a hand shut-off valve in the
Fan Speed Control:- Applicable to all units, both fans are speed controlled oil return line together with the relevant additional oil charge.
for more accurate head pressure control. Solenoid Valve and sight glass:- A N/C solenoid valve and sight glass
can be fitted in place of the hand shut-off valve on request.
Condensing Unit Housing Band Heater:- Can be fitted as an option on request (recommended for
units that are housed - external installation).
Metal housing fitted to the existing condensing unit base plate.
HP/LP Guages
Crankcase Heater
Fitted as standard to all HG/HA 4,5,6,7 & 8 cyl compressors. An HP & LP guage permanently fitted to the HP & LP side of the unit.
Guages suitable for R404A, R134a, R22.
12 Order Line : 01449 722274 January 2012