Factory Fitted Options - Available to special order
Condenser Fan Control Housing Oil Separator Options Crankcase
Condensing Auto HP switch Electronic Metal unit Standard System Solenoid Valve Oil Separator Heater
Unit Model (on/off) control speed controller housing c/w hand SOV & Sight Glass Heater band
RCS-AC03-ZF06K4E - RGE-Z1N4 CCH XW55824 1/4" 4" Band CH196 60w
RCS-AC03-ZF08K4E - RGE-Z1N4 CCH XW55824 1/4" 4" Band CH196 60w
RCS-AC06-ZF08K4E - RGE-Z1N4 AC06H XW55824 1/4" 4" Band CH196 60w
RCS-AC03-ZF09K4E - RGE-Z1N4 CCH XW55855 1/4" 4" Band CH196 60w
RCS-AC06-ZF09K4E - RGE-Z1N4 AC06H XW55855 1/4" 4" Band CH196 60w
RCS-AC06-ZF11K4E - RGE-Z1N4 AC06H XW55855 1/4" 4" Band CH196 60w
RCS-AC06-ZF13K4E - RGE-Z1N4 AC06H XW55855 1/4" 4" Band CH196 60w
RCS-AC07-ZF13K4E PS1-A5A RGE-Z1N4 AC07H XW55855 1/4" 4" Band CH196 60w
RCS-AC06-ZF15K4E - RGE-Z1N4 AC06H XW55855 1/4" 4" Band CH196 60w
RCS-AC07-ZF15K4E PS1-A5A RGE-Z1N4 AC07H XW55855 1/4" 4" Band CH196 60w
RCS-AC07-ZF18K4E PS1-A5A RGE-Z1N4 AC07H XW55855 1/4" 4" Band CH196 60w
RCS-AC08-ZF18K4E PS1-A5A RGE-Z1N4 AC08H XW55855 1/4" 4" Band CH196 60w
RCS-AC16-ZF24K4E PS1-A5A RGE-Z1Q4 AC16H XW55877 1/4" 4" Band CH196 60w
RCS-AC16-ZF33K4E PS1-A5A RGE-Z1Q4 AC16H XW55877 1/4" 4" Band CH196 60w
RCS-AC17-ZF33K4E PS1-A5A RGE-Z1Q4 AC17H XW55855 1/4" 4" Band CH196 60w
RCS-AC16-ZF40K4E PS1-A5A RGE-Z1Q4 AC16H XW55855 1/4" 4" Band CH196 60w
RCS-AC17-ZF40K4E PS1-A5A RGE-Z1Q4 AC17H XW55855 1/4" 4" Band CH196 60w
RCS-AC19-ZF40K4E PS1-A5A RGE-Z1Q4 AC19H XW55877 1/4" 4" Band CH196 60w
RCS-AC19-ZF48K4E PS1-A5A RGE-Z1Q4 AC19H XW55877 1/4" 4" Band CH196 60w
Factory Fitted Options - Specification : Oil Separator Options
Condenser Fan Control Standard System:- comprises an impingement type oil separator including a
vibration eliminator in the discharge line and a hand shut-off valve in the oil
HP On/Off control:- Only applicable to twin fan units and only one fan is return line together with the relevant additional oil charge.
controlled. Solenoid Valve and sight glass:- A N/C solenoid valve and sight glass can
Fan Speed Control:- Applicable to all units, both fans are speed controlled be fitted in place of the hand shut-off valve on request.
for more accurate head pressure control. Band Heater:- Can be fitted as an option. (recommended for units that are
housed - external installation).
Condensing Unit Housing
HP/LP Guages
Metal housing fitted to the existing condensing unit base plate.
An HP & LP guager permanantly fitted to the HP & LP side of the unit.
Crankcase Heater Guages suitable for R404A, R134a, R22.
A band heater can be fitted to the compressor on request.