Page 11 - Copeland Scroll Condensing Units
P. 11
Copeland Scroll Condensing Units
Factory Fitted Options - Available to special order
Liquid Line Options Suction Line Options Electrical HP/LP Guages
Drier & Solenoid Pump Down Insulated Suction H/X Condensing Unit Isolator Fitted to the Condensing
Sight Glass Valve LP Control Suction Line Accumulator 1 phase 3 phase Disch & Suct Unit Model
TD08 3/8" EVR 3 PS1-A3A 3/4" 18swg 3/4" x 3/8" 3 pole 20amp 6 pole 25amp 63mm Guages RCS AC03-ZB15KCE
TD08 3/8" EVR 3 PS1-A3A 3/4" 18swg 3/4" x 3/8" 3 pole 20amp 6 pole 25amp 63mm Guages RCS AC06-ZB15KCE
TD08 3/8" EVR 3 PS1-A3A 3/4" 18swg 3/4" x 3/8" 3 pole 20amp 6 pole 25amp 63mm Guages RCS AC03-ZB19KCE
TD08 3/8" EVR 3 PS1-A3A 3/4" 18swg 3/4" x 3/8" 3 pole 20amp 6 pole 25amp 63mm Guages RCS AC06-ZB19KCE
TD08 3/8" EVR 3 PS1-A3A 3/4" 18swg 3/4" x 3/8" 3 pole 20amp 6 pole 25amp 63mm Guages RCS AC07-ZB19KCE
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" 3 pole 25amp 6 pole 25amp 63mm Guages RCS AC03-ZB21KCE
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" 3 pole 25amp 6 pole 25amp 63mm Guages RCS AC06-ZB21KCE
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" 3 pole 25amp 6 pole 25amp 63mm Guages RCS AC07-ZB21KCE
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" 3 pole 25amp 6 pole 25amp 63mm Guages RCS AC06-ZB26K4E
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" 3 pole 25amp 6 pole 25amp 63mm Guages RCS AC07-ZB26K4E
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC06-ZB30KCE
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC07-ZB30KCE
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC08-ZB30KCE
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC06-ZB38K4E
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC07-ZB38K4E
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC08-ZB38K4E
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC07-ZB45K4E
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC08-ZB45K4E
TD084 1/2" EVR 6 PS1-A3A 7/8" 18swg 7/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC16-ZB45K4E
TD084 1/2" EVR 6 PS1-A3A 1.1/8" 18swg 1.1/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC08-ZB50K4E
TD084 1/2" EVR 6 PS1-A3A 1.1/8" 18swg 1.1/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC16-ZB50K4E
TD084 1/2" EVR 6 PS1-A3A 1.3/8" 18swg 1.3/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC08-ZB58K4E
TD084 1/2" EVR 6 PS1-A3A 1.3/8" 18swg 1.3/8" x 1/2" - 6 pole 25amp 63mm Guages RCS AC16-ZB58K4E
TD165 5/8" EVR 10 PS1-A3A 1.3/8" 18swg 1.3/8" x 5/8" - 6 pole 40amp 63mm Guages RCS AC16-ZB66K4E
ADK757 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 3/4" - 6 pole 40amp 63mm Guages RCS AC17-ZB66K4E
ADK757 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 3/4" - 6 pole 40amp 63mm Guages RCS AC19-ZB66K4E
ADK757 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 3/4" - 6 pole 40amp 63mm Guages RCS AC17-ZB76K4E
ADK757 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 3/4" - 6 pole 40amp 63mm Guages RCS AC19-ZB76K4E
ADK757 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 3/4" - - 63mm Guages RCS AC19-ZB95K4E
ADK757 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 3/4" - - 63mm Guages RCS AC19-ZB114K4E
ADK757 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 3/4" - - 63mm Guages RCS AC20-4p-ZB114K4E
TDS489 1.1/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 1.1/8" - - 63mm Guages RCS AC21-4p-ZB220K4E
Factory Fitted Options - Specification :
Liquid Line Options Suction Line Options
Drier and Sight Glass:- An appropriately sized liquid line will Suction Line:- An insulated suction line incorporating a vibration eliminator and anchoring
be installed from the receiver outlet to the extremity of the unit points will be insulated and capped off at the extremity of the condensing unit.
frame incorporating a filter drier and glass. This line will be Suction Accumulator/Heat exchanger:- This option includes a suction and liquid line
capped off once installed. terminated at the extremity of the unit incorporating a suction accumulator with an inbuilt heat
Solenoid Valve:- As an option a N/C solenoid valve will be exchanger.
added to the drier and sight glass option.
Pump-Down LP Control:- In order to control the condensing Electrical Isolator
unit in pump-down mode incorporating a solenoid valve an auto
reset LP control can be fitted, mounted on the frame of the This isolates the incoming power ONLY. Options including total isolation are available
condensing unit and wired to terminals in the compressor dependant on individual requirements.
terminal box.
January 2012 Order Line : 01449 722274 11