Factory Fitted Options - Available to special order
Condenser Fan Control Housing Oil Separator Options Crankcase
Condensing Auto HP switch Electronic Metal unit Standard System Solenoid Valve Oil Separator Heater
Unit Model (on/off) control speed controller housing c/w hand SOV & Sight Glass Heater
RCS 0.5-4AY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'A' Body
RCS 0.5-5AY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'A' Body
RCS 0.7-5AY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'A' Body
RCS 0.7-6AY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'A' Body
RCS 1-6AY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'A' Body
RCS 1-6AYH - RGE-Z1N4 AC06H XW55824 1/4" 4" Band 'A' Body
RCS 1-7AY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'A' Body
RCS 1.5-7AY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'A' Body
RCS 1.5-7AYH - RGE-Z1N4 AC06H XW55824 1/4" 4" Band 'A' Body
RCS 1.5-8AY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'A' Body
RCS 1.5-8AYH - RGE-Z1N4 AC06H XW55824 1/4" 4" Band 'A' Body
RCS 1.5-8AYHH PS1-A5A RGE-Z1N4 AC07H XW55824 1/4" 4" Band 'A' Body
RCS 1.5-9BY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'B' Body
RCS 1.5-9BYH - RGE-Z1N4 AC06H XW55824 1/4" 4" Band 'B' Body
RCS 1.5-10BY - RGE-Z1N4 CCH XW55824 1/4" 4" Band 'B' Body
RCS 1.5-10BYH - RGE-Z1N4 AC06H XW55824 1/4" 4" Band 'B' Body
RCS 2-10BY - RGE-Z1N4 AC06H XW55855 1/4" 4" Band 'B' Body
RCS 2-10BYH PS1-A5A RGE-Z1N4 AC08H XW55855 1/4" 4" Band 'B' Body
RCS 2-11DY - RGE-Z1N4 AC16H XW55855 1/4" 4" Band 'D' Body
RCS 2-11DYH PS1-A5A RGE-Z1N4 AC07H XW55855 1/4" 4" Band 'D' Body
RCS 2-11DYHH PS1-A5A RGE-Z1N4 AC08H XW55855 1/4" 4" Band 'D' Body
RCS 2-13DY - RGE-Z1N4 AC06H XW55855 1/4" 4" Band 'D' Body
RCS 2-13DYH PS1-A5A RGE-Z1N4 AC07H XW55855 1/4" 4" Band 'D' Body
RCS 2-15DY - RGE-Z1N4 AC06H XW55855 1/4" 4" Band 'D' Body
RCS 2-15DYH PS1-A5A RGE-Z1N4 AC07H XW55855 1/4" 4" Band 'D' Body
RCS 3-15DY PS1-A5A RGE-Z1N4 AC07H XW55855 1/4" 4" Band 'D' Body
RCS 3-15DYH PS1-A5A RGE-Z1N4 AC08H XW55855 1/4" 4" Band 'D' Body
RCS 3-15DYHH PS1-A5A RGE-Z1N4 AC16H XW55855 1/4" 4" Band 'D' Body
RCS 4-18DY PS1-A5A RGE-Z1N4 AC08H XW55877 1/4" 4" Band 'D' Body
RCS 4-18DYH PS1-A5A RGE-Z1N4 AC16H XW55877 1/4" 4" Band 'D' Body
RCS 3-19DY PS1-A5A RGE-Z1N4 AC07H XW55855 1/4" 4" Band 'D' Body
RCS 3-19DYH PS1-A5A RGE-Z1N4 AC08H XW55855 1/4" 4" Band 'D' Body
Factory Fitted Options - Specification :
Condenser Fan Control Oil Separator Options
HP On/Off control:- Only applicable to twin fan units and only one fan is Standard System:- comprises an impingement type oil separator
controlled. including a vibration eliminator in the discharge line and a hand shut-off
Fan Speed Control:- Applicable to all units, both fans are speed controlled valve in the oil return line together with the relevant additional oil charge.
for more accurate head pressure control. Solenoid Valve and sight glass:- A N/C solenoid valve and sight glass
can be fitted in place of the hand shut-off valve on request.
Condensing Unit Housing Band Heater:- Can be fitted as an option. (recommended for units that are
housed - external installation).
Metal housing fitted to the existing condensing unit base plate.
Crankcase Heater HP/LP Guages
A cartridge heater can be fitted to the compressor on request. An HP & LP guage permanently fitted to the HP & LP side of the unit.
Guages suitable for R404A, R134a, R22.
16 Order Line : 01449 722274 January 2012