Page 19 - Frascold Semi-Hermetic Condensing Units
P. 19
Frascold Semi-Hermetic Condensing Units
Factory Fitted Options - Available to special order
Liquid Line Options Suction Line Options Electrical HP/LP Guages
Drier & Solenoid Pump Down Insulated Suction H/X Condensing Unit Isolator Fitted to the Condensing
Sight Glass Valve LP Control Suction Line Accumulator 1 phase 3 phase Disch & Suct Unit Model
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 4-19DY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 4-19QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-19QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 4-20QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 4-21QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-21QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-21QYH
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-21QYHH
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 4-24QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 4-24QYH
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-24QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-24QYH
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-24QYHH
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 4-25QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-25QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-25QYH
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 25amp 63mm Guages RCS 5-25QYHH
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 40amp 63mm Guages RCS 7-25QY
TD 165 5/8" EVR 10 PS1-A3A 1.1/8" 18swg 1.1/8" x 5/8" - 6 pole 40amp 63mm Guages RCS 7-25QYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - 6 pole 25amp 63mm Guages RCS 5-28QY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - 6 pole 25amp 63mm Guages RCS 5-28QYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - 6 pole 40amp 63mm Guages RCS 7-28QY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - 6 pole 40amp 63mm Guages RCS 7-28QYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - 6 pole 25amp 63mm Guages RCS 5-33QY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - 6 pole 25amp 63mm Guages RCS 5-33QYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - 6 pole 40amp 63mm Guages RCS 7-33QY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - 6 pole 40amp 63mm Guages RCS 7-33QYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 7-36QY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 7-36QYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 7-39SY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 7-39SYH
Liquid Line Options Factory Fitted Options - Specification :
Drier and Sight Glass:- An appropriately sized liquid line will be Suction Line Options
installed from the receiver outlet to the extremity of the unit frame
incorporating a filter drier and glass. This line will be capped off Suction Line:- An insulated suction line incorporating a vibration eliminator and anchoring
once installed. points will be insulated and capped off at the extremity of the condensing unit.
Solenoid Valve:- As an option a N/C solenoid valve will be Suction Accumulator/Heat exchanger:- This option includes a suction and liquid line
added to the drier and sight glass option. terminated at the extremity of the unit incorporating a suction accumulator with an inbuilt
Pump-Down LP Control:- In order to control the condensing heat exchanger.
unit in pump-down mode incorporating a solenoid valve an auto
reset LP control can be fitted, mounted on the frame of the Electrical Isolator
condensing unit and wired to terminals in the compressor
terminal box. This isolates the incoming power ONLY. Options including total isolation are available
dependant on individual requirements.
January 2012 Order Line : 01449 722274 19