Page 21 - Frascold Semi-Hermetic Condensing Units
P. 21
Frascold Semi-Hermetic Condensing Units
Factory Fitted Options - Available to special order
Liquid Line Options Suction Line Options Electrical HP/LP Guages
Drier & Solenoid Pump Down Insulated Suction H/X Condensing Unit Isolator Fitted to the Condensing
Sight Glass Valve LP Control Suction Line Accumulator 1 phase 3 phase Disch & Suct Unit Model
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 10-39SY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 10-39SYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 8-42SY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 12-42SY
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 12-42SYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.3/8" 18swg 1.3/8" x 7/8" - Special Option 63mm Guages RCS 10-51SY
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 10-51SYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 15-51SY
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 15-51SYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 15-56SY
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 20-56SY
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 20-56SYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 15-59VY
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 20-59VY
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 20-59VYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 15-71VY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 25-71VY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 25-71VYH
ADK 757S 7/8" EVR 20 PS1-A3A 1.5/8" 18swg 1.5/8" x 7/8" - Special Option 63mm Guages RCS 20-84VY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 30-84VY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 30-84VYH
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 25-93VY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 32-93VY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 25-106ZY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 25-106ZYH
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 35-106ZY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 30-126ZY
TDS489 1.1/8" EVR 20 PS1-A3A 2.1/8" 16swg 2.1/8" x 1.1/8" - Special Option 63mm Guages RCS 30-126ZYH
Liquid Line Options Factory Fitted Options - Specification :
Drier and Sight Glass:- An appropriately sized liquid line will be Suction Line Options
installed from the receiver outlet to the extremity of the unit frame
incorporating a filter drier and glass. This line will be capped off Suction Line:- An insulated suction line incorporating a vibration eliminator and anchoring
once installed. points will be insulated and capped off at the extremity of the condensing unit.
Solenoid Valve:- As an option a N/C solenoid valve will be Suction Accumulator/Heat exchanger:- This option includes a suction and liquid line
added to the drier and sight glass option. terminated at the extremity of the unit incorporating a suction accumulator with an inbuilt
Pump-Down LP Control:- In order to control the condensing heat exchanger.
unit in pump-down mode incorporating a solenoid valve an auto
reset LP control can be fitted, mounted on the frame of the Electrical Isolator
condensing unit and wired to terminals in the compressor
terminal box. This isolates the incoming power ONLY. Options including total isolation are available
dependant on individual requirements.
January 2012 Order Line : 01449 722274 21